User ManualFor all Revolutions manufactured prior to May, 2007 (7160A1002).Rev EAugust 2008 © Copyright 2007. Electronic Theatre Controls, Inc.All rig
6 Source Four Revolution User ManualDimensions and Hanging Clearances344mm(13.5")317mm(12.5")454mm(17.9")394mm(15.5")400mm(15.7&qu
Overview 7Safety CableThe safety cable (or other approved safety device) should be secured to one of the handles on the upper enclosure, wrapped aroun
8 Source Four Revolution User ManualConnections and AddressingConnect AC input power and DMX data cables to the appropriate ports as shown below. Conn
Overview 9Power-up Procedure and CalibrationMove the power switch/breaker to the “on” position to apply power to the fixture. CAUTION:The Source Four
10 Source Four Revolution User ManualControlThe Source Four Revolution fixture can take as few as 14 and up to 31 DMX channels to operate. The table b
Overview 11Control Values for the Standard 12-Color Gel StringReset ChannelTo use the Reset Channel (Channel 12), set the channel to one of the levels
12 Source Four Revolution User ManualTiming ChannelsThree timing channels are provided: Focus Timing (Channel 9), Color Timing (Channel 10), and Beam
Configuration 13ConfigurationWith Source Four Revolution, you decide how to configure your light. The standard base unit provides pan, tilt, beam-edge
14 Source Four Revolution User ManualRemoving and Replacing ModulesEach module is secured with two thumbscrews. See the diagram below for bay designat
Configuration 15Blank Module (BM)The Blank Module is used to fill an empty module bay, and can be used to hold a static M-Size metal gobo, if needed.F
ETC, Source Four, Revolution, and QXL are registered trademarks of Electronic Theatre Controls, Inc. in the United States and other countries. Other p
16 Source Four Revolution User ManualIris Module (IM)The Iris Module contains an 18-leaf iris and can be placed in either module bay.
Configuration 17Shutter Module (SM)The Shutter Module contains a four-blade shutter mechanism. Each shutter can be rotated +/– 45° (total range of mot
18 Source Four Revolution User ManualStatic Wheel Module (SWM)The Static Wheel Module contains a wheel with three positions for static M-size steel or
Configuration 19Rotating Wheel Module (RWM)The Rotating Wheel Module contains a wheel with three rotating/indexing positions for static M-size steel o
20 Source Four Revolution User ManualControlling the Rotating Wheel ModuleThe Rotating Wheel Module uses two 8-bit channels to select the frame and de
Configuration 21Replacing Gobos and FiltersThe Static Wheel Module and the Rotating Wheel Module both use the same gobo/filter retention method. In ea
22 Source Four Revolution User ManualStep 6: Insert the spring into the frame. Ensure that the gobo/filter is held securely in place and that the spri
Routine Maintenance 23Routine MaintenanceTo ensure optimum performance of your Source Four Revolution fixture, you should perform the following inspec
24 Source Four Revolution User ManualProceduresScroller Cartridges and Beam Containment DevicesThe Source Four Revolution fixture is provided with a r
Routine Maintenance 25Installing or removing beam containment devices and color frames:Step 1: Push the latch on top of the scroller cartridge toward
Table of Contents iTable of ContentsSpecifications . . . . . . . . . . . . . . . . . . . . iiOverview . . . . . . . . . . . . . . . . . . . . . . . .1
26 Source Four Revolution User ManualStep 3: When the attachment tab on the left spool is revealed at the end of the leader, release the tab from the
Routine Maintenance 27Internal Media Frame (IMF)The internal media frame is designed to hold two pieces of gel within two semi-circular removable fram
28 Source Four Revolution User ManualStep 7: Remove the old media and replace the media in each frame. Trim the media to the shape of the frame. Trim
Routine Maintenance 29Note:If the spring clip does not allow enough movement, move the spring to the next notch in the clip.Step 7: When the pawl oper
30 Source Four Revolution User ManualChanging and Adjusting the LampThe QXL™ 750/77 lamp is remarkably easy to replace. No tools are required and the
Routine Maintenance 31Adjusting the lamp:Step 1: Apply power to the fixture and allow it to complete its calibration.Step 2: Bring intensity to full a
32 Source Four Revolution User ManualAdjusting Belt TensionsOver time and with repeated use, belts may loosen. Belts that are too loose may cause the
Routine Maintenance 33Adjusting pan belt tension:Step 1: Power-down the fixture (see Power-down Procedure, page 9) and disconnect any power and data c
34 Source Four Revolution User ManualAdjusting the Scroller, Front Lens, and Rear Lens BeltsTo access the three belts inside the head, you will need t
Routine Maintenance 35Adjusting the scroller drive belt tension:Step 1: See General belt adjustment instructions:, page 34.Step 2: Remove the scroller
ii Source Four Revolution User ManualSpecificationsPhysical• Die cast aluminum construction • High strength yoke for hanging in any orientation• Rugge
36 Source Four Revolution User ManualAdjusting the front lens belt:Step 1: See General belt adjustment instructions:, page 34.Step 2: Using both hands
Routine Maintenance 37Adjusting rear lens belt:Step 1: See General belt adjustment instructions:, page 34.Step 2: Using both hands, gently move the IM
38 Source Four Revolution User ManualTroubleshootingLED IndicatorsThe easiest way to find out the status of your Source Four Revolution fixture is to
Routine Maintenance 39Internal Test SoftwareThe following diagnostic tests are available using the thumbwheels on your Source Four Revolution fixture.
40 Source Four Revolution User Manual
Routine Maintenance 41
42 Source Four Revolution User Manual
Photometric DataMinimum SpreadMedian SpreadMaximum Spread37.2ft 44.7ft 52.1ft 59.6ft11.3m 13.6m 15.9m 18.2m10ft 12ft 14ft 16ft3.0m 3.7m 4.3m 4.9mFC 27
Corporate Headquarters 3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA Tel +608 831 4116 Fax +608 836 1736London,
Overview 1OverviewCongratulations on your purchase of the Source Four® Revolution™ fixture. Source Four Revolution has been engineered for maximum per
2 Source Four Revolution User ManualDocument ConventionsThroughout this manual, the following are used to alert you to notes and safety notices.Note:N
Overview 3SafetyThe Source Four Revolution high performance automated ellipsoidal spotlight is intended for professional use only. Read entire User Ma
4 Source Four Revolution User ManualInstallationPower and Data cabling requirementsThe Source Four Revolution fixture operates on AC power, 100-240VAC
Overview 5Installation proceduresInstalling hanging hardwareThe Source Four Revolution fixture’s upper enclosure provides six bolt holes for installat