Etc Unison ERn Wall-mount Control Enclosure User Manual

Browse online or download User Manual for Equipment Etc Unison ERn Wall-mount Control Enclosure. ETC Unison ERn Wall-mount Control Enclosure User Manual [en]

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Installation Manual

Copyright © Electronic Theatre Controls, Inc.All Rights reserved.Product information and specifications subject to change.Part Number: 7180M2100 Rev B

Page 2

6 Unison® ERn Wall Mount Enclosure Installation ManualPreparationsUnpack and InspectBefore you begin installation, check your shipment and confirm it

Page 3 - Table of Contents

1 Prepare for Installation 7General Lockout/Tagout Procedures:• Notify all affected employees that a lockout/tagout procedure is ready to begin.• Turn

Page 4

8 Unison® ERn Wall Mount Enclosure Installation ManualWhere to Install the EnclosureThe Unison External Processing Enclosure (ERn) can be wall (surfac

Page 5 - Introduction

1 Prepare for Installation 9Wire RequirementsWire Routing and SpecificationUnison ERn enclosures have conduit knockouts on the top and bottom for inco

Page 6 - ERn Modules and Options

10 Unison® ERn Wall Mount Enclosure Installation ManualThe following table lists the recommended control wire types used in a typical Unison installat

Page 7 - Description Notes

2 Install Rack Enclosures 11Chapter 2Install Rack EnclosuresThis chapter contains instructions for installation of the ERn enclosure and rough-in of c

Page 8 - Contacting ETC

12 Unison® ERn Wall Mount Enclosure Installation ManualInstall the Rack EnclosureThe wall must be strong enough to hold the rack fully populated with

Page 9 - Prepare for Installation

2 Install Rack Enclosures 13Rough-in Conduit and WiringRemove Option ModulesPrior to installing conduit and pulling wires into the ERn enclosure, remo

Page 10 - Preparations

14 Unison® ERn Wall Mount Enclosure Installation ManualRough-in Line and Control Conduit and WiringThe ERn enclosure requires line power and control w

Page 11 - Maximum Current Input

3 Terminate Wiring 15Chapter 3Terminate WiringThis chapter contains the following sections:• Connect Line Power Wiring . . . . . . . . . . . . . . .

Page 12 - Rack Dimensions and Weights

ETC®, Unison®, EDMX™ are either registered trademarks or trademarks of Electronic Theatre Controls, Inc. in the United States and other countries.Eche

Page 13 - Wire Requirements

16 Unison® ERn Wall Mount Enclosure Installation ManualConnect Line Power WiringERn enclosures are available in 100-120, 230 CE, and 240 VAC single ph

Page 14 - Data Types and Topologies

3 Terminate Wiring 17Connect Control WiringLow voltage data connects to pluggable connectors on the left and right input/output boards of the ERn encl

Page 15 - Install Rack Enclosures

18 Unison® ERn Wall Mount Enclosure Installation ManualConnect ERn Right I/O Data TerminationsTerminate DMX Control WiringDMX wire preparation and ter

Page 16 - Install the Rack Enclosure

3 Terminate Wiring 19DMX Input/Output Termination: Insulation Displacement ConnectorsThe graphic below illustrates DMX termination layout for an insul

Page 17 - Rough-in Conduit and Wiring

20 Unison® ERn Wall Mount Enclosure Installation ManualStep 2: Strip 3/16” (5mm) if insulation from the ends of each wire pair.Step 3: Remove the Link

Page 18 - CAUTION:

3 Terminate Wiring 21DMX TerminationDMX requires 120 termination at the last DMX device in the control run. Since an ERn enclosure with a Paradigm Ar

Page 19 - Terminate Wiring

22 Unison® ERn Wall Mount Enclosure Installation ManualConnect to Ethernet RJ-45Network interface to the ERn enclosure is made through the RJ-45 conne

Page 20 - Connect Line Power Wiring

4 Final Installation and Power Up 23Chapter 4Final Installation and Power UpThis chapter contains the following sections:• Check Main Power Wiring . .

Page 21 - Connect Control Wiring

24 Unison® ERn Wall Mount Enclosure Installation ManualCompleting the InstallationIt’s a good idea to look over the entire installation before applyin

Page 22 - Terminate DMX Control Wiring

4 Final Installation and Power Up 25Step 3: Open the ERn door and check voltage between phase, neutral, and ground. The ERn supports input power rangi

Page 23 - B A B A B A B A B A B A

Table of Contents iTable of ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . 1ERn External Processing Rack . . . . . . . . . .

Page 24 - Terminate Auxiliary Power

26 Unison® ERn Wall Mount Enclosure Installation ManualChapter 5Install Rack OptionsThis chapter contains the following sections:• Install the RideThr

Page 25 - 3 Terminate Wiring 21

5 Install Rack Options 27Rack OptionsUnison ERn options include the RideThru Option (URTO) kit, BatteryPack Option kit (UBPO), Ethernet Switch Module

Page 26 - Connect to Ethernet RJ-45

28 Unison® ERn Wall Mount Enclosure Installation ManualStep 1: Remove modules from the ERn enclosure for RideThru Option board installation access.• F

Page 27 - Chapter 4

5 Install Rack Options 29Install the BatteryPack Option (UBPO) KitStep 1: The BatteryPack Option board is provided with a wiring harness for connectio

Page 28 - Completing the Installation

30 Unison® ERn Wall Mount Enclosure Installation ManualStep 2: Install the Unison BatteryPack on to the bottom of the ERn enclosure as pictured below.

Page 29 - Final Installation

5 Install Rack Options 31Install a Paradigm Repeater or Dual Repeater ModuleBoth repeater module types may only be utilized in the top module slots of

Page 30 - Install Rack Options

32 Unison® ERn Wall Mount Enclosure Installation ManualTerminate LinkConnect Control WiringUnison control stations communicate with the Paradigm Archi

Page 31 - Rack Options

5 Install Rack Options 33Step 4: Loosen the terminal screws for as many wire pairs you are terminating. Keep in mind that the connector is split into

Page 32 - 28 Unison

34 Unison® ERn Wall Mount Enclosure Installation ManualStatus IndicatorsWhen power is applied to the ERn enclosure, the Paradigm Station Repeater Modu

Page 33 - 5 Install Rack Options 29

5 Install Rack Options 35Install Redundant Power SupplyThe ERn Redundant Power Supply (ERn-RPS) is an additional rack power supply that powers the ERn

Page 34 - 30 Unison

ii Unison® ERn Wall Mount Enclosure Installation ManualTerminate Contact Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . .22Final Installa

Page 35 - 5 Install Rack Options 31

36 Unison® ERn Wall Mount Enclosure Installation ManualInstall the Ethernet Switch ModuleThe ERn Ethernet Switch Module installs in the bottom option

Page 36

5 Install Rack Options 37Connect CAT5e WiringStep 1: Pull your CAT5e building wire through the conduit access previously prepared.Step 2: The punch do

Page 37 - 5 Install Rack Options 33

38 Unison® ERn Wall Mount Enclosure Installation ManualStatus IndicatorsWhen power is applied to the ERn enclosure, the Paradigm Ethernet Switch Modul

Page 38 - Status Indicators

5 Install Rack Options 39

Page 39 - 5 Install Rack Options 35

Corporate Headquarters  3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA  Tel +608 831 4116  Fax +608 836 1736London,

Page 40 - 36 Unison

Introduction 1IntroductionWelcome to the installation manual for the Unison® ERn Enclosure. This manual contains the procedures for safe and efficient

Page 41 - 5 Install Rack Options 37

2 Unison® ERn Wall Mount Enclosure Installation ManualERn Modules and OptionsModelPart NumberDescription NotesP-ACP 7180A1001 Paradigm Architectural C

Page 42

Introduction 3ERn-NET 7180A1400 ERn Ethernet Switch ModuleThe ERn Ethernet Switch (ERn-NET) provides four ports of 802.3af compliant Power over Ethern

Page 43 - 5 Install Rack Options 39

4 Unison® ERn Wall Mount Enclosure Installation ManualWarnings and Notice ConventionsThese symbols are used throughout this installation manual to ale

Page 44

1 Prepare for Installation 5Chapter 1Prepare for InstallationThis chapter contains the following sections:• Preparations . . . . . . . . . . . . . . .